This panel is a new-generation intelligent drawworks panel developed by our company. It has all the advantages of previous generations of panels and adds automatic control, automatic stop and alarm at the wellhead, segmented target-layer settings...



















XYQY-5-19 new automatic control panel instruction manual This panel is a new-generation intelligent drawworks panel developed by our company. It has all the advantages of previous generations of panels and adds automatic control, automatic stop and alarm at the wellhead, segmented target-layer settings and remote transmission, cloud storage, dual-channel input, and black box recording functions. (Remote transmission and black box functions are optional)
(1) The panel uses a DB37 connector. The wiring definitions are as follows: (2) The remote transmission internet interface uses an RJ-45 standard connector and port.
On the left side of the main interface, from top to bottom, are the depth, speed, tension, and tension increment windows. To the right of each window are the curves and progress bars corresponding to the data displayed in each window. The default maximum value of the depth progress bar and curve is 6000 meters. If modification is needed, it can be entered in the 5 target-layer setting boxes in system settings. For example, to set the layer from 2000 to 2030, enter 2000/2030. The system will use the largest main value entered in the 5 boxes as the maximum value of the depth curve and progress bar. The maximum values of the speed, tension, and tension differential progress bars and curves are the limit values set for these three items in the settings interface. Below, from left to right, the 5 blue boxes are the speed alarm indicator lights for the 5 target layers, and they turn red when alarming. Below are the cloud connection indicator, instruction manual, system settings, alarm release, start speed control, and the depth and tension windows of the other channel and the system time.
(1) Depth preset and reset: (figure below) Press and hold the depth window on the main interface for more than 1 second, and the system will pop up a depth setting dialog box. The user can preset the depth and reset it as needed. (2) Tension reset: Press and hold the tension window for more than 1 second to reset the tension. (3) Channel switching: (figure below) Tap the channel display box in the lower right corner of the main interface to switch the display of channels 1 and 2 on the main interface. Note: Black box recording, depth and tension output, and remote transmission only record and transmit the data of the channel displayed on the main interface.
(4) Automatic speed control: (figure below) Press "Start Speed Control" under the main interface button, and the system will pop up an automatic speed control dialog box. The user can set the automatic control speed as needed, and after the direction column, tap to select the direction to be automatically controlled. Then tap "Start" to start automatic control. After starting automatic control, if the speed needs to be adjusted, tap the adjustment button + or - under the main interface to adjust. After starting automatic control, if manual intervention is needed, the user only needs to adjust the control handle manually according to the current situation, and the system will automatically exit automatic control mode.
Note: Users are advised to use the automatic control function according to well conditions. Use it with caution when well conditions are unknown or complex! (5) Alarm release: used to release the current system alarm. (6) The lower right corner displays the current time. If connected to the internet, it can automatically synchronize the time. Left The indicator in the lower corner indicates that the system is connected to the internet.
(1) Parameter Settings: (see figure below) On the main interface, tap the "System Settings" button to enter the system settings interface. Under Channel 1 and Channel 2 respectively, input the pulse count, tension coefficient, limit tension, and tension differential from top to bottom. The limit speed parameter can be set once and is not separated. (The values here have been set at the factory according to the parameters of the Martin Decker provided. If any parameter abnormality is found, it can be restored by factory reset.) (2) Unit Conversion: (see figure below) Tap the currently displayed unit to the right of "Tension Unit", "Depth Unit", and "Speed Unit" respectively to select the unit to be used. The tension unit can be converted and switched in real time among kg, kn, and lb. The depth unit can be converted and switched in real time between m and foot, and the speed unit can be converted and switched in real time between h and min.
(3) Electronic Depth Reversal: (see figure below) In the lower left corner of the settings interface, there are "Channel 1" and "Channel 2" reversal keys; each tap reverses the display direction of the corresponding encoder. It can be adjusted as needed. (4) Chinese-English Conversion: Tap the "Chinese" and "English" keys to switch the system language to be displayed. (5) Depth Alarm Point Setting: (see figure below) On the system settings interface, tap "Next Page", and enter the required alarm points in the 5 entry boxes under the depth alarm point setting column. Note: The alarm points here only alarm during hoisting.
(6) Target Layer Setting and Target Layer Speed Setting: (see figure) Here, the 5 input boxes from left to right under the two settings "Target Layer Depth Setting" and "Target Layer Speed Setting" are associated with each other vertically, and "Target Layer Speed Setting" is associated with the 5 indicator lights in the lower left corner of the main interface. That is: the 1st target layer from the left corresponds to the 1st target layer speed from the left. If the 1st target layer from the left overspeeds, the 1st of the five blue square indicator lights in the lower left corner of the main interface
will turn red and alarm at the same time. The target layer setting format can be seen in the maximum value setting of the depth progress bar curve on the main interface. (7) Time Setting: (see figure below) Tap the current time displayed to the right of the time setting, and enter the time to be modified. The format is year-month-day space hour:minute:second. For example, for 16:11:27 on January 11, 2019, enter 2019-01-11 16:11:27. (8) Well Number and Vehicle Number Input: (see figure below) Enter the required well number and vehicle number in the input boxes below well number and vehicle number.
Note: After all the above system settings and parameter settings are completed, press the "Exit" key in the lower right corner to confirm. (9) Export Data: (optional) For panels with data recording function. After inserting the USB flash drive, tap the "Next Page" key on the settings interface, then tap "Export Data"; the system will pop up a dialog box, and you can export the data within the required time according to the export options. (see figure below) (10) Brightness Adjustment: To avoid eye discomfort caused by the panel screen being too bright during night operation, users can adjust the brightness bar left and right as needed to adjust the screen brightness.
(11) Viewing Serial Number, User Name, and Software/Hardware Version: On the settings interface, press "Device Version" to view. (see figure below) The instructions are complete. Thank you for reading.
| Signal | Description | Signal | Description | ||
| 1 | GND | System power supply GND | 20 | Relay | NC |
| 2 | DC24VI/12VI | System power | 21 | RXD232 | Serial port receive |
| 3 | TXD232 | Serial port transmit | 22 | GND | Serial port GND |
| 4 | AGND | Signal GND | 23 | AGND | Signal GND |
| 5 | 5VO | Encoder 5V power | 24 | 5VO | Encoder 5V power |
| 6 | AI1+ | Encoder 1 A+ | 25 | BI1+ | Encoder 1 B+ |
| 7 | AI2+ | Encoder 2 A+ | 26 | BI2+ | Encoder 2 B+ |
| 8 | AGND | Encoder GND | 27 | AGND | Encoder GND |
| 9 | 12VO | Tensiometer 12V power | 28 | 12VO | Tensiometer power |
| 10 | ZLI1 | Tensiometer 1 signal | 29 | ZLI2 | Tensiometer 2 signal |
| 11 | AGND | Tensiometer GND | 30 | AGND | Tensiometer GND |
| 12 | AO | Encoder output A | 31 | BO | Encoder output B |
| 13 | ZLO | Tension signal output | 32 | ||
| 14 | AGND | Signal output GND | 33 | ||
| 15 | HCAI | Drawworks handle input A | 34 | HCAO | Drawworks handle output A |
| 16 | HCBI | Drawworks handle input B | 35 | HCBO | Drawworks handle output B |
| 17 | BREAKI | Drawworks brake signal input | 36 | BREAKO | Drawworks brake signal output |
| 18 | COM | Relay COM | 37 | NC | Relay NC |
| 19 | NO | Relay NO |

ZNJL2025-I Winch Metering System

ZNJL2013-I Winch Metering Instrument (Martin Decker)

ZNJL2003-I Winch Metering Instrument (Martin Decker)

ZNJL2000-II Winch Metering Instrument (Martin Decker)

ZNJL2010-III Winch Metering Instrument (Martin Decker)

ZNJL2008-I Winch Metering Instrument (Martin Decker)

ZNJL98-I Winch Metering Instrument (Martin Decker)

ZNJL2006-I Winch Metering Instrument (Martin Decker)