1.1 After connecting the intelligent panel and the depth meter without error according to the wiring shown in 2, power can be turned on for operation.



ZNJL2005- Technical Parameters of the Intelligent Swabbing Metering System
1.1 After connecting the intelligent panel and the depth meter without error according to the wiring shown in 2, power can be turned on for operation. Press the power key and the indicator light comes on; the depth digital display then shows ****.* (this is the memory of the previous instantaneous depth value). Set it to zero according to the operating instructions; the speed and swabbing count will both show zero.
Example: set pulse count/per meter = 960, value is 0960.0 Press the pulse/per meter key → press the set key → press 0 → press 9 → press 6 → press 0 → press 0. Finally press the pulse count/per meter key; the number shown in the depth window is the value to be set.
Example: set target zone depth = 6000 m, value is 6000.0 Press the target zone depth key → press the set key → press 6 → press 0 → press 0 → press 0 → press 0. Finally press the target zone depth key; the number shown in the depth window is the value to be set. Warning: the target zone depth must not be set to 0000.0 or 9999.9; otherwise, a system depth error will be caused.
Example: set limit speed = 9000 m/h, value is 9000. Press the limit speed key → press the set key → then press 9 → press 0 → press 0 → press 0. Finally press the limit speed key; the number shown in the speed window is the value to be set.
Example: depth zeroing: press the instantaneous depth key → press the set key → press 0 → press 0 → press 0 → press 0 → press 0.
When you set a new well number, the swabbing count in the previous well number is zeroed accordingly. 1.7 Use the panel keys to check and modify the pulse count, limit speed, target zone depth, instantaneous depth, tension K value and swabbing count zeroing. After settings are correct, the unit can be put into use.
Turn the measuring wheel; the panel should display depth. If it is turned ten revolutions counterclockwise, the panel should display: 10M; then turn it 10 revolutions clockwise, and the depth display should all be 0. 2. Wiring diagram and wire color definitions between the intelligent winch panel and its installed equipment cables: Encoder wire definitions: pin 1 5V pin 2 ⊥ pin 3 encoder signal A pin 5 encoder signal A NOT pin 6 encoder signal B pin 7 encoder signal B NOT
Pulse count refers to the number of pulses output by the photoelectric encoder per one meter of rotation of the measuring wheel (not per revolution). If the circumference of the measuring wheel becomes smaller after long-term use, and an actual well depth of 3000M is measured by the measuring wheel as 3010M, the "pulse count" must be corrected. Then: new pulse count = 3010×1280/3000
Select new pulse count 1284.27 pulses/m
Press the well number key → set key →□□□□ four-digit well number. In the operation panel well number setting, up to four well numbers can be set, and only the most recent four well number records are retained. 4.2 When collecting data, insert the USB flash drive (it must be a formatted USB flash drive), and turn the switch to the data collection side. After hearing four alarm sounds, data collection starts; after hearing eight alarm sounds, data collection is complete. First turn off the switch, then remove the USB flash drive. Note: if a long alarm sound is heard during collection, it indicates a USB flash drive fault and data collection cannot be completed.
4.3 During lowering, the instrument panel should display positive numbers. If it is the opposite, insert the encoder input plug into the other socket, and it will be positive. 4.4 When using a USB flash drive to collect data, the original data in the USB flash drive will be automatically deleted. Be sure to use an empty USB flash drive for data collection. 4.5 During operation, the switch must be turned to the working state side for normal operation. If it is turned to the data collection end, the panel will stop working normally.
Press the time key → set → the first digit of depth flashes) input year, month, day, hour, minute, second in sequence. (two digits each) Example: 12 year month day hour minute second
Before each recorder is used, the USB flash drive should be formatted as FAT32 (specific method: right-click My Computer - Manage - Disk Management - Format USB flash drive, where Volume label (V): blank; File system: FAT32; Allocation unit size: 1024) The USB recorder is used for winch panels with standard serial output Precautions for use and maintenance
Installation position: the pulley body is required to be higher than the oil pit; under no circumstances should the pulley body be immersed in the oil-water ditch;
Inject grease once every 7 working days, using a manual grease gun, 7-8 injections are sufficient. Under no circumstances should too much grease be injected, so as not to affect the normal operation of the photoelectric encoder;
When finished with each well, it can only be wiped clean with cotton yarn and must not be washed with water, so as to prevent water from entering the photoelectric encoder;
When operation is abnormal, first check the pulley area, and whether the connecting line, socket and plug wires are loose or broken.
The three M16 set screws on the side plate must be tightened before operation
The swabbing count record is designed such that lowering greater than 200 meters records half a swabbing, and lifting to less than 20 meters from the wellhead records one swabbing Xianyang Xiyi Qinyou Petroleum Equipment Co., Ltd.
| Main Technical Parameters | Technical Parameters |
| Cable travel mode | Curve |
| Applicable wire rope | φ13——φ25 |
| Measuring wheel circumference | 1000 mm |
| Photoelectric encoder | Range: 0——9999.9 Accuracy: better than 0.1% |
| Pulse count: 960 /m | |
| Dimensions (L×W×H) | 460 × 350 × 800 mm |
| Self-weight | 50 kg |
| Operating temperature | -45 ℃ ——+70℃ |
| Brief application | Swabbing, oil recovery |
| Remarks | It has display and recording functions for swabbing, time, depth, speed, well number and swabbing count |
| Common Faults and Troubleshooting | ||
| Fault | Troubleshooting Method | Remarks |
| Instrument panel does not light | 1. The positive and negative poles of the power supply are connected in reverse; the instrument panel red wire is +, black wire is -. | |
| 2. The fuse is blown; there is a knob on the front of the panel; unscrew it and replace the fuse. | ||
| 3. The supply voltage is DC 12V. | ||
| Instrument panel alarms | 1. Among the pulse count, target zone depth, limit speed and limit ten- | |
| sion, if any one is set to zero, an alarm will occur. 2. In the working state, the switch must not be turned to the data collection end; it should be turned to the working end. | ||
| Depth inaccurate | 1. Zero the position before swabbing in each well. | |
| 2. The pulse count setting should be 09600 for accuracy. 3. Check whether the encoder coupling shaft is loose. (as shown in the figure below) | ||
| 1. Check whether the pulse count is set; | It is recommended that each crew prepare | |
| Panel depth and speed | 2. Check whether the connecting line is connected or broken; | one electric soldering iron and |
| do not work | 3. Check whether the encoder socket wire ends on the swabbing wheel are loose; | a multimeter. |
| 4. Whether the photoelectric encoder coupling shaft is loose. | ||
| Method for inserting the encoder plug | Align the notch and only tighten the top thread half a turn (quick plug) | |
| 1. Excessive grease injection; a large amount of grease entering the encoder will cause | Recommendation: add grease once every three days; | |
| Photoelectric encoder is prone to damage | damage to the encoder; | 3-4 strokes with a manual grease gun are sufficient. |
| Causes | 2. Oil mud and water must not be allowed to enter the encoder; | |
| 3. When not in use, the protective cover should be installed on the encoder socket. | ||
| 1. Photoelectric encoder; | ||
| Wear parts | 2. Photoelectric encoder socket, tension gauge aviation plug; | |
| 3. Measuring wheel. |

ZNJL2025-I Winch Metering System

ZNJL2013-I Winch Metering Instrument (Martin Decker)

ZNJL2003-I Winch Metering Instrument (Martin Decker)

ZNJL2000-II Winch Metering Instrument (Martin Decker)

ZNJL2010-III Winch Metering Instrument (Martin Decker)

ZNJL2008-I Winch Metering Instrument (Martin Decker)

ZNJL98-I Winch Metering Instrument (Martin Decker)

ZNJL2006-I Winch Metering Instrument (Martin Decker)